- You can pierce isolation of a cable by means of a control lamp with needle contact and establish, what cables are energised.
- Choose the electroscheme corresponding to the required switch.
- At first it is necessary to check up, whether запитаны switches; for this purpose it is necessary to include ignition or illumination some times.
- Then it is checked, whether spends the switch in corresponding position pressure further on a chain.
- On an example of the switch of the lock of ignition check looks as follows:
- To remove a combination of devices that wires became accessible.
- To connect a wire of a control lamp to "weight".
- To pierce a control needle isolation of a checked wire.
- Both thick red wires of the plug 30 should be constantly energised the accumulator.
- The grey-yellow plug of the R-chain is in rest position the ignition lock energised, at turn of a key food giving stops.
- The black-yellow wire of plug H is energised exclusively in key position ignition is included; as well as a thin red wire to a buzzer of a parking light and radio.
- Black wire of the plug 15 запитан in positions ignition is included and "start".
- The red-black wire of the plug 50 orders of start of a starter of the engine is energised only in position "start".
|
|